1dl code on goodman furnace - The CoolCloud HVAC application allows contractors to connect and communicate wirelessly via Bluetooth with Goodman and Amana premium air handler and furnace control boards. This provides a more efficient means for servicing and maintaining equipment, making configuration adjustments, gaining equipment status, performing diagnostics, viewing ...

 
To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.. Alternative before it

Remove the access panel on your Trane furnace. Locate the dirty air filter. It should be near the return air duct or the blower chamber’s entrance. Remove the old air filter and slide in a new one. Ensure that signifiers indicate that the new filter is installed correctly. Replace the panel or door to your Trane furnace.To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ...May 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. I have a Amana AM9C960603ANAA. I'm getting 2 codes on the LCD display. First is 1dl and the second one is EE5. What do - Answered by a verified HVAC TechnicianMar 26, 2022 · I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace. My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023. Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician Jan 18, 2014 · GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open). I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire …View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14...Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace... AC furnace brands AC furnaces, also known as central air conditioning systems, are important to home comfort and energy efficiency. Many AC furnace brands are on the market, each with strengths and weaknesses. Trane is a popular AC furnace brand known for its... Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... Mar 23, 2017 · Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43. The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.Goodman is one of the biggest names i...Mar 1, 2022 · Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control. Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.4th of July Deals - Purchase Your HVAC Equipment Direct ... The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ... My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.Display Codes D3 – Airflow CFM Mismatch Diagnostic Description Indoor air movers (air handlers / furnaces) cannot supply the airflow required for proper system operation. Possible Cause Misplaced indoor air mower-replacement with incorrectly sized air handler / furnace.Purchase Your HVAC Equipment Direct | Goodman AC And Furnace ...To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.ERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil.STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ...Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, orfailed ...Some simple Diy troubleshooting a Goodman furnace with no flame and the computer board putting out a number 1 flash code.Amazon link to Great products that e...Turn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43.67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre...Dec 17, 2015 · I need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t... Remove the access panel on your Trane furnace. Locate the dirty air filter. It should be near the return air duct or the blower chamber’s entrance. Remove the old air filter and slide in a new one. Ensure that signifiers indicate that the new filter is installed correctly. Replace the panel or door to your Trane furnace.4th of July Deals - Purchase Your HVAC Equipment Direct ... GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read moreItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.I have a Amana AM9C960603ANAA. I'm getting 2 codes on the LCD display. First is 1dl and the second one is EE5. What do - Answered by a verified HVAC TechnicianApr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace.Feb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour.As an armature, I have some experience troubleshooting furnace problems. I have a 1.5 ton Goodman furnace that cools and heats. The circuit bd. Is B25578-00A. The unit is 25 years old and has been wor … read more4th of July Deals - Purchase Your HVAC Equipment Direct ... Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.Trane furnace code 1dl. Troubleshooting a Trane furnace with code 1DL is a common challenge homeowners face. Code 1DL stands for “Inadequate Diffuser Pressure Switch Closure” and can occur due to problems with the furnace blower motor, evaporation motor, heat exchanger or other related components.Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. The rollout switches detect heat where it shouldn’t be. Faulty switches are indicated by nine flashes on the Goodman furnace LED. You can try replacing your furnace filter or contact technicians if it does not work. Call Immediate Services To Fix Your Furnace Issues Today. You may be able to fix most of your furnace issues by following the ... F1. Failed Electronic Range Control (ERC) Repair Electronic Range Control (ERC) F2. Oven too hot. Replace oven temperature sensor. F3, F4. Shorted or open oven temperature sensor. F5, F6, F8.Apr 14, 2022 · 1dl code has appeared on our Goodman ac, Yes to both. Since last night, reset everything, ... I hav e GMV95 Goodman Furnace and air about 6 months old. Air has worked ... Jan 4, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. Goodman error code 7P1 is IDLSTATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read moreView and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14... Post Tags: # Furnace # Goodman # Goodman Furnace Minhazul Abedin With an extensive background and experience in various aspects of construction and renovation, he has established himself as a trusted authority in creating beautiful and functional living spaces.HVAC Technician: RobHVAC. No problem. Or you can just touch the two terminal screws together with the wire until the unit turns on. Ask Your Own HVAC Question. FO4 IRC it turned on. HVAC Technician: RobHVAC. OK so that means that the issue is the thermostat not the unit.To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ... Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. Purchase Your HVAC Equipment Direct | Goodman AC And Furnace ... The Goodman furnace error code 1dl is a common error code associated with Goodman furnaces that indicates a problem with the hot surface ignitor. When this error code appears, it usually indicates that the hot surface ignitor has failed and needs to be replaced. This article will provide an overview of this error code and discuss how to ... Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...operating both with a Nest Smart thermostat about 8-10 yrs old…heating program always ran fine with Lennox…now the program doesn't always work…thermostat is lit up showing it's calling for heat but furnace is not running…I turn thermostat off and back on and furnace starts to run…To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes.CODE: b9. RESULT: Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match. CODE: d0. RESULT: Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data. CODE: d1.To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.https://www.alwaysopen.caGoodman Furnace Fault CodesTo receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ... We recently had a new Goodman furnace installed. We have an old programmable Honeywell thermostat. The problem I'm having now is that the thermostat reads 68 (is set to 75) and the furnace isn't comin … read moreMay 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long.The CoolCloud HVAC application allows contractors to connect and communicate wirelessly via Bluetooth with Goodman and Amana premium air handler and furnace control boards. This provides a more efficient means for servicing and maintaining equipment, making configuration adjustments, gaining equipment status, performing diagnostics, viewing ... The rollout switches detect heat where it shouldn’t be. Faulty switches are indicated by nine flashes on the Goodman furnace LED. You can try replacing your furnace filter or contact technicians if it does not work. Call Immediate Services To Fix Your Furnace Issues Today. You may be able to fix most of your furnace issues by following the ... 1dl code has appeared on our Goodman ac, Yes to both. Since last night, reset everything, ... I hav e GMV95 Goodman Furnace and air about 6 months old. Air has worked ...Apr 12, 2015 · This one covers the IFC error codes for most Trane furnaces. This video is part of the heating and cooling series of training videos made to accompany my we...

specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When furnace duct(s) supply air outside the space contain-ing the furnace, a return air duct must terminate in the same space as the supply duct and be sealed to the furnace casing. A gas-fired furnace for installation in a residential garage. Ipxtrwxd

1dl code on goodman furnace

ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace...Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating.The controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not UsedTurn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.Feb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. Nov 29, 2014 · A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre... My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.Feb 25, 2023 · Goodman error code 7P1 is IDL How to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter. No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.Goodman error code 7P1 is IDLNo Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.View the user manual below for more details. Want a copy for yourself? Download or print a free copy of the user manual below. GAS FURNACE (INSTALLOPERATING) (viewing) Download PDF. Owner’s Manual. Top Parts. Models. Showing 10 of 12 parts. Show.ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.Oct 16, 2021 · Code 1-3: Indicates that a limit flame switch problem that normally auto-resets after 3 hours. Code 1-4: Represents an ignition problem. However, the furnace will auto-reset after some hours. Code 2-1: This is a sign of gas heating lockout. You need to check if the gas valve wiring is correct. goodman air conditioner error codesI need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t....